Description
Method adapted from EPA method 1312 for solid phase non-volatile extractions in wastewater using synthetic acid precipitation to simulate metal mobility under rainwater conditions.
Typical Equipment
- H₂SO₄
- HNO₃
- 0.991 cm sieve
- ICP-AES
Output Measurements
- leachable metal concentrations